Sensor · Lightning
Lightning sensor
Integrated with the FieldPRO station, it uses the quasi-electrostatic principle to detect cloud-to-ground, intracloud and cloud-to-cloud strikes up to 35 km away and to identify strong electric fields, flagging the risk before the first strike. Three dry-contact relays (alert, warning and fault) can trigger sirens and stoppages right on site.
What it measures
- Cloud-to-ground, intracloud and cloud-to-cloud strikes
- Storm distance
- Strong electric field, before the first strike
Specifications
- Detection range
- 35 km
- Distance resolution
- 1 km
- Detection efficiency
- 95% with 1 strike, 99.9% with 3
- False alarm rate
- Below 2%
- Update rate
- 2 s
- Output
- Isolated RS-422, up to 1,000 m
- Relays
- 3 dry-contact (alert, warning and fault), 35 VDC, 5 A
- Power supply
- 9 to 30 VDC
- Consumption
- Below 6 W
- Operating temperature
- −20 to 50 °C
- Relative humidity
- 0 to 100%
- Maximum wind
- 60 m/s
- Protection
- IP66 (IEC 60529)
- Material
- Stainless steel and epoxy-coated aluminum
- Dimensions
- 675 mm tall, 200 mm in diameter, 4.3 kg
- Installation
- Ø46 to 53 mm mast, 1.5 m high, grounded
- Maintenance
- Automatic self-test, inspection every 6 to 12 months
- Certifications
- CE, UKCA, EN 61326-1, EN 50536 (Class 1), IEC 62793 (Class A), RoHS and WEEE